FLUKE 15B+ DIGITAL MULTIMETER 1000V AC/DC MODEL # 15B+

AED 0

  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Voltage, resistance, continuity, capacitance

FLUKE

  • Brand

    FLUKE
  • Model Number

     15B+
  • Type

    Digital Multimeter
  • AC/DC Volts

    4-1000V
  • Resistance

    400.0 O to 40.0 MO
  • Capacitance

    40.0 nF - 1000 µF

   add to cart

Share on:

  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold

 

ACCURACY SPECIFICATIONS

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

Function

Range

Resolution

Accuracy

AC volts

(40 Hz to 500Hz)14.000 V

40.00 V

400.0 V

1000 V0.001 V

0.01 V

0.1 V

1 V

1.0% + 3

DC volts

4.000 V

40.00 V

400.0 V

1000 V0.001 V

0.01 V

0.1 V

1 V

0.5% + 3

AC millivolts

400.0 mV

0.1 mV

3.0% + 3

DC millivolts

400.0 mV

0.1 mV

1.0% + 10

Diode test2

2.000 V

0.001 V

10%

Resistance

(Ohms)400.0 Ω

4.000 kΩ

40.00 kΩ

400.0 kΩ

4.000 MΩ

40.00 MΩ0.1 Ω

0.001 kΩ

0.01 kΩ

0.1 kΩ

0.001 MΩ

0.01 MΩ0.5% + 3

0.5% + 2

0.5% + 2

0.5% + 2

0.5% + 2

1.5% + 3

Capacitance3

40.00 nF

400.0 nF

4.000 μF

40.00 μF

400.0 μF

1000 μF0.01 nF

0.1 nF

0.001 μF

0.01 μF

0.1 μF

1 μF2% + 5

2% + 5

5% + 5

5% + 5

5% + 5

5% + 5AC current μA

(40 Hz to 400 Hz)400.0 μA

4000 μA0.1 μA

1 μA

1.5% + 3

AC current mA

(40 Hz to 400 Hz)40.00 mA

400.0 mA0.01 mA

0.1 mA

1.5% + 3

AC current A

(40 Hz to 400 Hz)4.000 A

10.00 A0.001 A

0.01 A

1.5% + 3

DC current μA

400.0 μA

4000 μA0.1 μA

1 μA

1.5% + 3

DC current mA

40.00 mA

400.0 mA0.01 mA

0.1 mA

1.5% + 3

DC current A

4.000 A

10.00 A0.001 A

0.01 A

1.5% + 3

Backlight

Yes

1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.

2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.

3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).

Function

Overload protection

Input impedance (Nominal)

Common mode rejection ratio

Normal mode rejection ratio

AC volts

1000 V 1

>10 MΩ <100 pF

>60 dB at dc,

50 Hz or 60 Hz

AC millivolts

400 mV

>1MΩ, <100 pF

>80 dB at 50 Hz or 60 Hz

DC volts

1000 V 1

>10 MΩ <100 pF

>100 dB at dc,

50 Hz or 60 Hz

>60 dB at 50 Hz or 60 Hz

DC millivolts

400 mV

>1MΩ, <100 pF

>80 dB at 50 Hz or 60 Hz

1 106 V Hz Max

General specifications

Maximum voltage between any terminal and earth ground

1000 V

Display (LCD)

4000 counts, updates 3/sec

Battery type

2 AA, NEDA 15A, IEC LR6

Battery life

500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)

Temperature

Operating

0 °C to 40 °C

Storage

-30 °C to 60 °C

Relative humidity

Operating humidity

Non-condensing (<10°C)

≤90% RH at 10 °C to 30 °C;

≤75% RH at 30 °C to 40 °C40 MΩ range

≤80% RH at 10 °C to 30 °C;

≤70% RH at 30 °C to 40 °C

Altitude

Operating

2000 m

Storage

12,000 m

Temperature coefficient

0.1 X (specified accuracy) /°C (<18 °C or >28 °C)

Fuse protection for current inputs

440 mA, 1000 V Fast Fuse, Fluke specified part only.

11A, 1000V Fast Fuse, Fluke specified part only.

Size (H x W x L)

183 x 91 x 49.5 mm

Weight

455 g

IP rating

IP 40

Safety

IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2

Electromagnetic environment

IEC 61326-1: Portable

Electromagnetic compatibility

Applies to use in Korea only

Class A equipment (industrial broadcasting & communication equipment)1

1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or

user should take notice of it. This equipment is intended for use in business environments and is not to be