FLUKE 106 PALM-SIZED DIGITAL MULTIMETER – 600V MODEL # 106

AED 0

  • Voltage; resistance; continuity; capacitance
  • Input terminal for ac and dc current measurements to 10 A and current
  • Data hold

FLUKE

  • Brand

    FLUKE
  • Model Number

     106

   add to cart

Share on:

  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A and current
  • Data hold

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])

Accuracy Specifications

Function

Range

Resolution

Accuracy

AC Volts

(40 Hz to 500Hz)16.000 V

60.00 V

600.0 V0.001 V

0.01 V

0.1 V

1.0 % + 3

DC Volts

6.000 V

60.00 V

600.0 V0.001 V

0.01 V

0.1 V

0.5 % + 3

AC Millivolts

600.0 mV

0.1 mV

3.0 % + 3

Diode Test2

2.000 V

0.001 V

10 %

Resistance

(Ohms)400.0 Ω

4.000 kΩ

40.00 kΩ

400.0 kΩ

4.000 MΩ

40.00 MΩ0.1 Ω

0.001 kΩ

0.01 kΩ

0.1 kΩ

0.001 MΩ

0.01 MΩ0.5 % + 3

0.5 % + 2

0.5 % + 2

0.5 % + 2

0.5 % + 2

1.5% + 3

Capacitance3

50.00 nF

500.0 nF

5.000 μF

50.00 μF

500.0 μF

1000 μF0.01 nF

0.1 nF

0.001 μF

0.01 μF

0.1 μF

1 μF2 % + 5

2 % + 5

5 % + 5

5 % + 5

5 % + 5

5 % + 5Frequency4 Hz

(10 Hz – 100 kHz)50.00 Hz

500.0 Hz

5.000 kHz

50.00 kHz

100.0 kHz0.01 Hz

0.1 Hz

0.001 kHz

0.01 kHz

0.1 kHz

NA

Duty Cycle4

1 % to 99 %

0.1 %

NA

AC Current

(40 Hz to 200 Hz)4.000 A

10.00 A0.001 A

0.01 A

1.5 % + 3

DC Current

4.000 A

10.00 A0.001 A

0.01 A

1.5 % + 3

  1. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
  3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
  4. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.

Function

Overload Protection

Input Impedance (Nominal)

Common Mode Rejection Ratio

Normal Mode Rejection Ratio

AC Volts

600 V 1

>10 MΩ <100 pF 2

>60 dB at dc,

50 Hz or 60 Hz

\AC Millivolts

600 mV

>1M, <100 pF

>80 dB at 50 Hz or 60 Hz

DC Volts

600 V 1

>10 MΩ <100 pF

>100 dB at dc,

50 Hz or 60 Hz

>60 dB at 50 Hz or 60 Hz

  1. 6 x 105 V Hz Max
  2. For mV (AC), input impedance is approximately 1 MΩ.

General Specifications

Maximum Voltage Between any Terminal and Earth Ground

600 V

Display (LCD)

6000 counts, updates 3/sec

Battery Type

2 AAA, NEDA 24A, IEC LR03

Battery Life

200 hours minimum

Temperature

Operating

0 °C to 40 °C

Storage

-30 °C to 60 °C

Relative Humidity

Operating Humidity

Non-condensing when <10°C

≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C

Operating Humidity, 40 MΩ Range

≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C

Altitude

Operating

2000 m

Storage

12,000 m

Temperature Coefficient

0.1 X (specified accuracy) /°C (<18 °C or >28 °C)

Fuse Protection for Current Inputs

11A, 1000V Fast Fuse, Fluke specified part only

Size (HxWxL)

142 mm x 69 mm x 28mm

Weight

200 g

IP Rating

IEC 60529: IP 40

Safety

IEC 61010-1: 600 V CAT III, Pollution Degree 2

Electromagnetic Environment

IEC 61326-1: Portable

Electromagnetic Compatibility

Applies to use the Korea only.  Class A Equipment (Industrial Broadcasting and Communication Equipment)1

  1. This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.
Posthemes

09/07/2019

demo

That's OK!

Add a review

Your email address will not be published. Required fields are marked